FUSING
5 Charge Conditions
These depend on whether auto process control is switched off or on.
Process Control Off
Depends on the settings of the following SP codes:
SP2001 008
SP2001 009
Process Control On
Depends on the voltage setting of SP2001 010.
The current grid voltage as a result of process control can be checked SP3902 004
(Process Control Display - VG). From this value for VG (SP3902 004 – SP2001
010) , the value of the minus VL correction (SP3902 013) and the value of SP2001
010 (the value for the bias grid is determined for line speed of 350 mm/s) and VL is
adjusted for 350 mm/s (low speed mode).
6 Development Bias Conditions
The development potential for low speed mode is determined by subtracting the
value of SP2201 008 from the value for SP2201 004.
8 ID Pattern Interval and LD Exposure Level
Uses the settings of SP2104 002 (LD Power Adjustment for ID Sensor Pattern –
Low Speed).
Others
• Leading edge registration: SP1001 003 and 004
• Fusing unit web motor (how often it turns on): SP1902 005