Tech Service Bulletin No. B070/B071 – 014
3. Attach one 100 µm spacer in the front of the unit. Print out the pattern again and compare with the
sample from Step 2.
If the ID variation along the mainscan direction decreases (improves) but is still visible, attach
another 100 µm spacer in the same position.
Rear
Front