Gestetner B070 Service Manual page 387

Table of Contents

Advertisement

Rev. 06/2004
SP
1002
005
006
007
008
1003
Paper Buckle Adjustment (Registration)
001
002
003
1008
1103
1105
Fusing Temperature Adjustment
001
002
003
004
005
SM
CÓPIA NÃO CONTROLADA
Number/Name
5th Tray (LCT Tray 2)
6th Tray (LCT Tray 3)
7th Tray (Bypass Tray)
Duplex Tray (Copier)
Copier Paper Tray
LCT
Duplex Tray
Duplex Fence Adjustment
Fusing Idling After Energy Saving
Fusing Temperature in Waiting
Condition
Fusing Temperature Lower Limit
Fusing Temperature Correction
(< A4 / LT)
Fusing Temperature Correction
(>A4 / LT)
Fusing Temperature Correction
(Transparencies)
CÓPIA NÃO CONTROLADA
SERVICE PROGRAM MODE TABLES
Function/[Setting]
[-9.0~+9.0 / -0.8/ 0.1 mm]
[-9.0~+9.0 / +0.3 / 0.1 mm]
[-9.0~+9.0 / -0.3 / 0.1 mm]
[-9.0~+9.0 / 0 / 0.1 mm]
Adjusts the relay clutch timing at
registration. The relay clutch timing
determines the amount of paper buckle
at registration. (A plus or minus setting
increases or decreases the amount of
buckle.)
[-9~+9 / +4 / 1 mm]
[-9~+9 / +4 / 1 mm]
[-9~+9 / +4 / 1 mm]
Adjusts the distance between the front
and rear duplex fences.
[-2.0~+2.0 / 0 / 0.5 mm]
Selects whether fusing idling is done or
not when recovering from the Energy
Saving. [0~1 / 0 / 1]
0: Not Done
1: Done
Adjusts the fusing temperature for stand-
by.
B070: [120~178/ 168/ 1 deg]
B071: [120~178 / 173 / 1 deg]
Adjusts the fusing temperature lower
limit. When the fusing unit falls below this
temperature, the machine stops copying.
Copying automatically restarts when the
fusing temperature recovers.
DFU
B070: [100~158 / 148 / 1 deg]
B071: [100~158 / 153/ 1 deg]
Specifies the amount to raise the fusing
temperature from standby mode to print
on paper smaller than A4/LT LEF.
B070: [0~10 / 7 / 1 deg]
B071: [0~10 / 10 / 1 deg]
Specifies the amount to raise the fusing
temperature from standby mode to print
on paper of A4/LT width LEF or wider.
B070: [0~10 / 2 / 1 deg] (B070)
B071: [0~10 / 5 / 1 deg] (B071)
Note: The threshold paper width used for
SP1105 003 and 004 depends on
SP1105 010.
Specifies the amount to raise or lower
fusing temperature from standby mode to
print on OHP Transparencies.
B070: [-10~+5 / +2 / 1 deg] (B070)
B071: [-10~+5 / +5 / 1 deg] (B071)