Tech Service Bulletin No. B070/B071X – 001
Note:
While the "Op. panel" firmware is being updated, the panel display will be blank (progress bar not
displayed). Also, the Power ON LED will flash as follows:
- During the update: LED flashes on and off at 0.5s intervals.
- After the update is completed: LED flashes on and off at 3s intervals.
It takes about 4 to 4.5 minutes to complete the "Op. panel" firmware update. The total time for all
four updates is approximately 9 minutes.
6.
Turn the main switch OFF.
7.
Remove the SD card from the C3 slot.
8.
Turn the main switch ON.
9.
Enter SP mode:
1. Press the Clear Modes key .
2. Press
3. Hold down the Clear key
4. Press Copy SP.
10. Check the firmware version to confirm that the firmware has been successfully downloaded
(SP7801):
Note: As mentioned above under Step 4, if the BIOS firmware could not be updated at the same time (was
not displayed), please repeat the above procedure to update the
Important:
If the customer does not use NetWare server, please change the "NetWare" setting to
"Invalid" in User Tools.
User Tool --> System Setting --> Interface Setting --> Effective Protocol NetWare –> Select
"Invalid" –> Exit –> Main SW off/on