SC862 HDD Error 3: Bad Sectors
Definition [A]
The number of bad sectors on the HDD in the area for storing images exceeds
101.
Possible Causes
• Too many bad sectors accumulated on the HDDs.
NOTE: 1) Execute SP5832 002 (HDD Formatting – IMH) to format the HDD and
replace the bad sectors; copy the stamp data after doing this (use SP
5853).
2) HDD replacement is recommended because an HDD unit that
generates bad sectors is probably of poor quality and performs poorly.
SC863: HDD Error 4: HDD Read Error
Definition [B]
The system cannot read the data written on the hard disks.
Possible Causes
• Sectors on the disks have become corrupted during operation; replace the
hard disks
SC864: HDD Error 5: Data CRC Error
Definition [B]
During HDD operation, the HDD could not respond to a CRC error query.
Possible Causes
• Mother board defective
SC865: HDD Error 6: Access Error
Definition [B]
HDD responded to an error during operation for a condition other than those for
SC863, 864.
Possible Causes
• HDD defective
SM
CÓPIA NÃO CONTROLADA
4-49
CÓPIA NÃO CONTROLADA
SERVICE CALL CONDITIONS