SC914: External Controller Error 5
Definition [D]
Not used.
SC919: External Controller Error 6
Definition [B]
While EAC (External Application Converter), the conversion module, was operating
normally, the receipt of a power line interrupt signal from the FLUTE serial driver
was detected, or BREAK signal from the other station was detected.
Possible Causes
• Power outage at the EFI controller
• EFI controller was rebooted
• Connection to EFI controller loose
SC920: Printer Error 1
Definition [D]
An internal application error was detected and operation cannot continue.
Possible Causes
• Software defective; switch off/on, or change the controller firmware if the
problem is not solved
• Insufficient memory
SC921: Printer Error 2
Definition [D]
When the printer application started, the font to use could not be found on the SD
card.
Possible Causes
• The font is not on the SD card