SERVICE PROGRAM MODE TABLES
Function/[Setting]
Displays the acquired value when the
potential sensor is calibrated after
application of
-700V.
Determines whether VD correction is
performed. DFU
[0~1 / 0/ 1]
0: No Correction. Correction with value of
SP2001 007 only
1: Correction with value of SP2001 007 +
50V
Displays the value of VL at auto process
control initialization.
Displays the amount of correction (∆VLref)
according to results of the VL detection at
auto process control.
Displays the latest value of VL.
Displays the amount of correction (∆VLref)
according to the latest VL detection results.
Displays the value of the current image
development bias output, determined by the
results of VL detection.
Adjusts the starting point for the VD
Correction. Displays whether the VD
correction is being performed. The target
value for VD correction is "the value of SP2-
001-7 + 50".
[0~999 / 200 / 1 K copies]
The counter is automatically reset to 0
(zero) when SP2-801 is performed.
Function/[Setting]
Adjusts the magnification in the sub scan
direction for scanning. If this value is
changed, the scanner motor speed is
changed. ( 3-17)
[-0.9~+0.9 / 0 / 0.1 percent]
Use the "
/ *key to enter the minus ( –)
before entering the value.
Setting a lower value reduces the motor
speed and lengthens the image in the sub
scan direction (paper direction). Setting a
larger value increases the motor speed
and shortens the image in the sub scan
direction.