6.6.10 ADF JAM CONDITIONS

[A]
[B]
Feed-in
1. The entrance sensor [A] is still off 500 ms after the feed-in motor turned on.
2. The registration sensor [B] is still not off 300 ms after the feed-in motor speed
increased.
3. The entrance sensor is still on when the feed-in and transport motors have fed
the original 442 mm after the registration sensor turned on.
Feed-out
4. The registration sensor is still on when the feed-in and transport motors have
fed the original 751 mm after the registration sensor turned on.
5. The exit sensor [C] is still off when the transport and feed-out motors have fed
the original 129 mm after the feed-out motor turned on.
6. The exit sensor is still on when feed-out motor has fed the original X mm
(X = original length x 1.3) after the exit sensor turned on.
Inversion
7. The exit sensor is still off when the transport and exit motors have fed the
original 198 mm after the transport motor turned on to feed the original to the
inverter section.
8. The exit sensor is still on when the feed-out motor has fed the original X mm
(X = original length x 1.3) after the exit sensor turned on.
9. The inverter sensor [D] is still off when the transport and feed-out motors have
fed the original 96 mm after the exit sensor turned on.
10. The inverter sensor is still off when the transport and feed-out motors have fed
the original 96 mm to the exposure glass after the exit sensor turned off.