Tech Service Bulletin No. B070/B071 – 011
Auto Process Control: B070/B071
NOTE:
The following explanation applies to the B070/B071 and A294/A295/A294ll/A295ll, except for the values that differ from model to model mentioned in
Section 4.
EXECUTION CONDITIONS
There are three separate cases in which the machine performs Auto Process Control:
1.
When it is executed manually from SP2962 (Auto Process Control Execution).
2.
When SP3901-001 (Auto Process Control Setting) has been set to ON, and the fusing temperature is detected at 100
NOTE:
If the fusing temperature is higher than 100
3.
When all of the following conditions have been met:
a.) SP2966 (Periodical Auto Process Control) has been set to ON
b.) 24hrs has passed since the last time Auto Process Control was performed
c.) The main power has been ON during this 24hr period
* Auto Process Control is then performed at the end of the job following the 24hr mark.
CÓPIA NÃO CONTROLADA
o
C at this time, the previous auto process control data is used.
CÓPIA NÃO CONTROLADA
o
C or less at power up.