NOTE: 1) Before discarding the SD card, try to update the data on the card. If the
error occurs again, the card may be defective.
2) Be sure to use an SD card that contains the correct electronic
signature.
SC818 Watch Dog Error
Definition [B]
While the system program is running, a bus hold or interrupt program goes into an
endless loop, preventing any other programs from executing.
Possible Causes
• System program defective; switch off/on, or change the controller firmware if
the problem cannot be solved
• Controller board defective
• Controller option malfunction
SC819 Fatal kernel error
Definition [B]
RAM overflow occurs during system processing. One of the following messages is
displayed on the operation panel.
NOTE: For more details about this SC code error, execute SP5990 to print an
SMC report so you can read the error code. The error code is not displayed
on the operation panel.
SMC Report Error Code: 0x696e
init died
SMC Report Error Code: 0x766d
vm_pageout: VM is full
Possible Causes
• Controller board defective
• Software defective; change the controller firmware