KEY CARD COUNTER
18. Connect the extension cable [A] from the LCT to the copier.
19. Dock the LCT to the copier.
User Tool and SP Mode Settings
1. Instruct the key operator to enable the key counter with the User Tools setting:
User Tools> System Settings> Key Counter Management> then click the ON
button for the items you want to enable for the counter (Copier, Document
Server, Printer, Scanner).
2. Enter the SP mode and set SP5113 (Optional Counter Type) to 002 (Key Card
(Countdown Type)) or 005 (MF Key Card).
NOTE: If the counter is a countdown type, you must select 002.
3. Enter the SP mode and set SP5121 to "0" (Paper Feed Count) or "1" (Paper
Exit Count) to determine whether the counter counts at paper feed-in or a paper
exit.
B070/B071
CÓPIA NÃO CONTROLADA
1-98
CÓPIA NÃO CONTROLADA
Rev. 06/2003
[A]
B070I210.WMF