Rev. 06/20/2003
[D]
[E]
11. Insert one end of the interface cable [A] to the connection PCB inserted in slot
A2.
12. If additional interface cables are required, connect the cables [B] with the
repeater hubs [C].
13. On the operation panel of the both machines, remove the second cover (or
Printer key) from the bottom [D].
14. Install an appropriate key for each machine:
Attach the "Printer/Other Function" key [E] (or its equivalent symbol keytop for
EU) if the printer/scanner option is installed in the machine.
-or-
Attach the "Other Function" key [E] (or its equivalent symbol keytop for EU) if
the printer/scanner is not installed in the machine.
15. Attach the other end of the connection cable to the connection PCB installed in
the other machine.
⇒
16. The following software must be downloaded onto both the master and slave
machine.
• SYSTEM Ver. V3.04.1(install first) or later
• NCS (NIB) Ver. 4.13.3 or later
• NetFile Ver. 3.04.2 or later
• BCU (Engine) V4.01.1 or later
• LCDC (NA, EU) Ver. 2.09 or later
NOTE: For details about downloading procedures, see Section "5. Service
Tables" of the Service Manual.
SM
CÓPIA NÃO CONTROLADA
INSTALLATION OF MFP CONTROLLER OPTIONS
[A]
[C]
[B]
1-89
CÓPIA NÃO CONTROLADA
T03040804.WMF
B070/B071