3.7.4 DRUM POTENTIAL SENSOR

1. Remove the drum unit. (!3.7.1)
NOTE: Before removing the drum potential sensor, put a few sheets of paper
between the sensor and the drum to protect the drum surface.
2. Drum potential sensor [B] and the grounding plate [C] ( x 2,  x 1).
3. Execute SP2962 (Auto Process Control Execution).
NOTE: After replacing the drum potential sensor, you must always execute SP
2962.