6.16.8 FUSING PRESSURE

[A]
[D]
B070D557.WMF
[F]
Fusing pressure is constantly applied between the hot roller [A] and pressure roller
[B] by the upper pressure lever [C] and lower pressure lever [D], which are lifted by
the fusing unit release lever [E] via the pressure cam [F]. The pressure can be
adjusted by using the pressure adjustment screw [G].
The fusing pressure is released by turning the fusing unit release lever
counterclockwise.
SM
CÓPIA NÃO CONTROLADA
[B]
[E]
[G]
[C]
[D]
6-141
CÓPIA NÃO CONTROLADA
FUSING
[D]
[F]
[G]
[C]
[F]
B070D556.WMF
B070/B071
[G]
[C]