QoS Commands
Defaults
parameter
filter
shutdown
Platforms Supported
OmniSwitch 6400, 6850, 6850E, 6855, 9000E
Usage Guidelines
Use the no form of this command to disable the filter or shutdown function. This form of the command
effects the overall operation of the feature.
To specify more than one traffic type in the same command line, enter each type separated by a space
(e.g., spoof bgp ospf).
Note that existing traffic types to filter or shutdown are removed each time the filter or shutdown
option is configured. Specify all desired traffic types each time the qos user-port command is
performed to retain previously configured traffic types.
No changes to the filtering and shutdown options are applied to the switch until the qos apply
command is performed.
This command only applies to ports that are members of the UserPorts group. Use the policy port
group command to create and assign members to the UserPorts group.
An SNMP trap is sent when a port is administratively disabled through a UserPorts shutdown function
or a port disable action.
To enable a port disabled by a user port shutdown operation, use the
administratively enable the port or disconnect and reconnect the port cable.
Up to 126 IP interfaces are supported with spoof detection on user ports. If the number of interfaces
exceeds this amount, user port packets ingressing on those interfaces that exceed the 126 limit are
dropped.
Examples
-> qos user-port filter spoof bpdu
-> qos user-port shutdown spoof bgp ospf
-> qos no user-port shutdown
Release History
Release 6.1.1; command was introduced.
Release 6.3.1; dvmrp, pim, isis, and dns-reply parameters added.
OmniSwitch CLI Reference Guide
default
spoof
none
June 2012
interfaces admin
command to
page 32-19