Section 4 Settings Required for Basic Control
4.2 Set Values
The value selected for each parameter is called the set value. There are two types of set values: numbers
and characters. Set values are displayed and changed as follows:
1
25.0
1300.0
01.01
1
25.0
-200.0
01.01
1
25.0
250.0
01.01
4-6
Changing a Numeric Set Value
1. Press the U Key continuously to increase the set value.
When the upper limit of the setting is reached, the set value will flash and
cannot be increased any further.
2. Press the D Key continuously to decrease the set value.
When the lower limit of the setting is reached, the set value will flash and
cannot be decreased any further.
3. Follow steps 1 and 2 to change the set value to the desired value.
The setting is saved 2 seconds after it is changed, or when a key other
than the U or D Key is pressed.
When setting the Manual MV parameter, the set value is output every
50 ms. The set value is saved as described above.