Omron E5AR-T User Manual page 37

Programmable digital controller
Hide thumbs Also See for E5AR-T:
Table of Contents

Advertisement

Section 2 Preparations
E5AR-TC43DW-FLK (2-loop Controller)
100 to 240 VAC
A
1
!
2
3
4
5
6
B( )
1
1
RS-485
OUT2
A( )
2
2
Current output
3
3
4 to 20 mA DC, 500
max.
4
0 to 20 mA DC, 500
max.
4
(Switched by output
5
type setting.)
5
6
OUT1
F
6
Current output
F
4 to 20 mA DC, 500
max.
0 to 20 mA DC, 500
max.
(Switched by output type setting.)
E5AR-TCCE3MWW-FLK (4-loop Controller)
100 to 240 VAC
24 VAC/DC
!
A
1
2
Input power supply
3
depends on model.
4
100 to 240 VAC or 24
VAC/DC (no polarity)
5
6
1
B( )
1
RS-485
OUT2
A( )
2
2
Current output
3
4 to 20 mA DC, 500
max.
3
0 to 20 mA DC, 500
max.
4
4
(Switched by output
5
type setting.)
5
6
OUT1
F
G
Current output
6
4 to 20 mA DC, 500
max.
F
0 to 20 mA DC, 500
max.
(Switched by output type setting.)
1
OUT4
Current output
Input 2(K)
2
4 to 20 mA DC, 500
max.
Input 4(J)
0 to 20 mA DC, 500
max.
3
(Switched by output
4
type setting.)
OUT3
5
Input 1(K)
Current output
Input 3(J)
4 to 20 mA DC, 500
max.
6
0 to 20 mA DC, 500
max.
G
(Switched by output type setting.)
Note: With the E5AR-T, the power supply voltage must be 100 to 120 V for UL compliance. With
the E5AR-T, the power supply voltage must be 100 to 240 V for CE marking compliance.
2-6
Auxiliary outputs
(Relay outputs)
B
1
COM
B
C
D
E
2
SUB1
3
SUB2
4
COM
5
SUB3
6
SUB4
Event inputs
E
1
2
EV3
EV4
3
EV5
4
G
H
I
J
K
5
EV6
COM
6
1
2
Input 2
3
I
V
PT
TC
4
5
Input 1
6
I
V
K
PT
TC
(Current) (Voltage)
(Thermocouple)
(Platinum resistance thermometer)
Auxiliary outputs
(Transistor outputs)
B
C
1
COM
SUB1(B), SUB6(C)
2
B
C
D
E
SUB2(B), SUB7(C)
3
4
SUB3(B), SUB8(C)
SUB4(B), SUB9(C)
5
SUB5(B), SUB10(C)
6
D
E
Event inputs
1
2
EV3(E), EV7(D)
3
EV4(E), EV8(D)
4
EV5(E), EV9(D)
H
I
J
K
5
EV6(E), EV10(D)
COM
6
1
2
3
+
I
V
PT
T C
4
5
6
I
V
PT
TC
(Thermocouple)
(Current) (Voltage)
J, K
(Platinum resistance thermometer)
E5AR-TQQE3MW-FLK (2-loop Controller)
24 VAC/DC
100 to 240 VAC
+
!
A
B
C
D
1
2
Input power supply
3
depends on model.
100 to 240 VAC or 24
4
VAC/DC (no polarity)
5
6
1
B( )
1
RS-485
2
OUT2
A( )
2
Voltage output 12 V
3
3
40 mA
4
4
OUT1
5
Voltage output 12 V
5
6
40 mA or
6
Current output
F
G
H
I
J
F
4 to 20 mA DC, 500
max.
0 to 20 mA DC, 500
max.
(Switched by output type setting.)
1
OUT4
2
Voltage output 12 V
Input 2
3
40 mA
I
OUT3
4
Voltage output 12 V
5
40 mA or
Input 1
Current output
6
4 to 20 mA DC, 500
max.
G
I
0 to 20 mA DC, 500
max.
(Switched by output type setting.)
(Current) (Voltage)
(Platinum resistance thermometer)
E5AR-TQQE3MWW-FLK (4-loop Controller)
100 to 240 VAC
A
B
C
1
!
2
3
4
5
6
B( )
1
1
RS-485
OUT2
A( )
2
2
Voltage output 12 V 21 mA
3
3
4
4
OUT1
Voltage output 12 V
5
5
21 mA or
6
Current output
6
F
G
H
I
4 to 20 mA DC, 500
max.
F
0 to 20 mA DC, 500
max.
(Switched by output type setting.)
1
OUT4
2
Input 2(K)
Voltage output 12 V 21 mA
Input 4(J)
3
OUT3
4
Voltage output 12 V
5
21 mA or
Input 1(K)
Current output
6
Input 3(J)
4 to 20 mA DC, 500
max.
G
0 to 20 mA DC, 500
max.
(Current) (Voltage)
(Switched by output type setting.)
(Platinum resistance thermometer)
Auxiliary outputs
(Transistor outputs)
C
B
1
COM
E
SUB1(B), SUB6(C)
2
SUB2(B), SUB7(C)
3
SUB3(B), SUB8(C)
4
SUB4(B), SUB9(C)
5
SUB5(B), SUB10(C)
6
Event inputs
D
E
1
2
EV3(E), EV7(D)
3
EV4(E), EV8(D)
4
EV5(E), EV9(D)
K
EV6(E), EV10(D)
5
COM
6
1
2
3
V
PT
TC
4
5
6
PT
K
V
TC
(Thermocouple)
Auxiliary outputs
(Transistor outputs)
B
C
1
COM
D
E
SUB1(B), SUB6(C)
2
SUB2(B), SUB7(C)
3
4
SUB3(B), SUB8(C)
5
SUB4(B), SUB9(C)
SUB5(B), SUB10(C)
6
D
E
Event inputs
1
2
EV3(E), EV7(D)
EV4(E), EV8(D)
3
EV5(E), EV9(D)
4
J
K
5
EV6(E), EV10(D)
6
COM
1
2
3
I
V
PT
TC
4
5
6
I
V
PT
TC
(Thermocouple)
J, K

Advertisement

Table of Contents
loading

This manual is also suitable for:

E5er-t

Table of Contents