Advertisement

● Monitor/Setting
Item
PF1 Monitor/Setting Item 1
Setting
pf1.1
Item 5
pf1.5
pVsp
l.adf
off
l.adf
PF2 Monitor / Setting Item 1
Setting
pf2.1
Item 5
pf2.5
pVsp
l.adf
off
l.adf
5.4 Display and Key Adjustment Functions
* The default settings for the function keys are as follows:
PF1 Setting: r-r (Run/Reset)
PF2 Setting: prg (Program)
The default setting is
channel.
* With the exception of the "Select Program," "Monitor/Setting Item,"
and "
Key" settings, the function keys are effective only in the
CH
following levels: Operation, Program Setting, Adjustment,
Adjustment 2, Alarm Set Setting, PID Setting, Time Signal Setting,
Approximation Setting, Monitor Item, and Protect Levels.
• A key set for "Program" is effective only in Operation Level.
• A key set for "Monitor/Setting Item" is effective only in Protect
Level.
• A key set for "
CH
The keys are effective only when the PF Key Protection parameter is
set to "OFF."
* Operation Adjustment Protection and Setting Change Protection
do not apply to the function keys.
Parameter settings can be changed and saved using function keys
if the key is set to the corresponding function.
The PF1 Setting or PF2 Setting parameter can be set to pfdp
(Monitor/Setting Item) to display monitor/settings using a function key.
The content to be displayed is set for each channel in the Monitor/
Setting Item 1 to Monitor/Setting Item 5 parameters of the corre-
sponding function key.
The selections are shown in the following table. Refer to the descrip-
tions of individual parameters for the setting or monitor ranges.
Set value
Description
OFF
Disabled
PVSP
PV/SP/MV
PVDV
PV/Deviation
SEG.R
Remaining Segment Time
P
Proportional Band (P)
I
Integral Time (I)
D
Derivative Time (D)
AL-1
Alarm 1
AL1H
Alarm Upper Limit 1
AL1L
Alarm Lower Limit 1
AL-2
Alarm 2
AL2H
Alarm Upper Limit 2
AL2L
Alarm Lower Limit 2
AL-3
Alarm 3
AL3H
Alarm Upper Limit 3
AL3L
Alarm Lower Limit 3
AL-4
Alarm 4
AL4H
Alarm Upper Limit 4
AL4L
Alarm Lower Limit 4
Key for models with more than one input
CH
Key" is effective in all levels.
Remarks
Monitor/Setting
Can be set (SP)
Monitor only
Monitor only
Can be set
Can be set
Can be set
Can be set
Can be set
Can be set
Can be set
Can be set
Can be set
Can be set
Can be set
Can be set
Can be set
Can be set
Can be set
Display
seg.r
p
i
d
al-1
al1h
al1l
al-2
al2h
al2l
al-3
al3h
al3l
al-4
al4h
al4l
5-21