Omron E5AR-T User Manual page 415

Programmable digital controller
Hide thumbs Also See for E5AR-T:
Table of Contents

Advertisement

Appendix
A-46
*1: When the control mode is changed, added channels are initialized
in the same way as the related parameters for the Input Type
parameter ( on the previous page).
*2: This is the upper and lower limit of the sensor setting range. For a
temperature input, this is 4 to 20 mA.
*3: If this is PV or SP based on the PID Set Automatic Selection Data
parameter, then (setting upper limit + setting range
DV, then (setting range
*4: Initialized only if the control mode is changed to proportional
control (Temperature: Initializes to upper and lower limits of
sensor setting range. Analog: Initializes to values set for Scaling
Display Values 1 and 2 parameters).
*5: Upper/lower limit of sensor setting range and Scaling Display
Values 1 and 2 parameters are initialized.
*6: The default setting is 0.
*7: The corresponding alarm type numbers in all alarm sets are
initialized to 0.
*8: If the Closed/Floating parameter is set to "Float" for position-
proportional control, or if the Operation at Potentiometer Input
Error parameter is set to "Continue," this is initialized if the integral
time is 0.
*9: If the applicable channel is used for heating/cooling control, this is
100%, otherwise it is 0%. (Therefore in cascade heating/cooling
control, the primary loop is 0% and the secondary loop is 100%.)
*10 All programs and segment parameters will be initialized.
*11 All programs and segment parameters will be initialized when the
Number of Segments parameter is changed.
*12 The following segments will be initialized when the Step Time/
Rate of Rise Programming parameter is set to rate of rise
programming. (Nothing will be initialized when this parameter is
set to step time.)
When Operation at Reset parameter is set to "Control Stop": All
odd segments
When Operation at Reset parameter is set to "Fixed Control": All
even segments
*13 The following segments will be initialized when the Step Time/
Rate of Rise Programming parameter is set to rate of rise
programming. All segments will be initialized when this parameter
is set to step time.
When Operation at Reset parameter is set to "Control Stop": All
odd segments
When Operation at Reset parameter is set to "Fixed Control": All
even segments
*14 Initialized only when the Program Output Selection parameter is
set for segment outputs.
*15 Initialized only when the Program Output Selection parameter is
set for time signals.
1.1).
0.1); if it is