3.2 Coordinated Electric Oven Operation
With Models with Four Input Channels, coordinated operation can be performed based on channel 1.
Operation is programmed using the same program for all channels. Offsets can be set for channels 2 to 4.
■ Application
■ Wiring
Traditionally, three programmable temperature Controllers were
required to control electric ovens in three zones. With the E5AR-T/ER-
T, however, only one Controller is required for coordinated operation as
long as the same program is used. Here, the E5AR-TCCE3MWW-FLK
is used.
Channel 1 Program
Broken-line program
SP
SUB1 SUB2 SUB3 SUB4
WA IT
IN1
8.8.8.8.8
8
CH
8.8.8.8.8
IN2
8.8.8.8
CMW
OUT1 OUT2 OUT3 OUT4 RST
IN3
PF1
PF2
RUN/RST
Sensor
Heater
Sensor
Heater
Sensor
Heater
3.2 Coordinated Electric Oven Operation
Time
FSP
OUT1
PV
SV
OUT2
PRG.
SEG
RSP
HOLD
OUT3
E
5
AR
E5AR-T
100 to 240 V AC
G3PX
Power Controller
4 to 20 mA
G3PX
Power Controller
4 to 20 mA
G3PX
Power Controller
4 to 20 mA
Power Controller
Power Controller
Power Controller
AB
C
D
E
1
1
2
2
3
3
4
4
5
5
6
6
1
1
2
IN2
2
3
3
OUT2
4
4
5
IN3
IN1
5
OUT1
OUT
6
6
FG
H
I
J
K
3-7