Program Settings - Omron E5AR-T User Manual

Programmable digital controller
Hide thumbs Also See for E5AR-T:
Table of Contents

Advertisement

■ Program Settings

SP Start
● Setting Procedure
Program Setting Level
prg.n
1
01.00
s-no
Number of
Segments Used
8
6
01.00
seg.n
Segment Editing
end
01.00
sp
Segment
Set Point
200.0
01.01
time
Segment Time
1.00
01.01
wait
Wait
off
01.01
The following program is used in this example.
1400
1200
1000
800
600
400
200
0
1 h
1 h
1.5 h
Segment 1
Segment 2
Segment 3
1. Press the L Key for less than 1 second to move to the Program Setting
Level. prg.n (Program Editing) will be displayed. Set the program number
to 1.
2. Press the M Key to select 5-no (Number of Segments Used). Press the
D Key to select 6 segments.
3. Press the M Key to select seg.n (Segment Editing). Change from end to
1.
4. Press the M Key to select sp (Segment Set Point). Press the U Key to set
the set point to 200.0.
5. Press the M Key to select tine (Segment Time). Press the U Key to set
the time to 1.00.
6. Press the M Key to select wait (Wait). Make sure the setting is off.
3.1 Standard Control
1 h
2 h
1 h
Segment 4
Segment 5
Segment 6
End Condition:
Continue
3-5