Section 8 Parameters

8.14 Alarm Setting Level (

This level contains parameters for the type and output operation of alarms, including alarm types, close in
alarm/open in alarm settings, and latch settings.
● Level Changes at Startup Up To Alarm Setting Level
Power on
Power on
Program
Operation
Setting
Level
Level
L key less
L key less
than 1 s
L key
L key
25.0
1 s
3 s
0.0
or more
or more
01.01
Input Initial
Control Initial
Setting
Setting
Level
l.0
l.1
Level
L key
less than 1 s
● Parameter Changes within Alarm Setting Level
Alarm Setting Level
CH
alt1
ALT1: Alarm 1 Type
0 to 11
2
M
CH
A1LT: Alarm 1 Latch
a1lt
OFF/ON
off
M
CH
ALH1:
alh1
Alarm 1 Hysteresis
0.02
0.01 to 99.99
M
CH
alt2
ALT2: Alarm 2 Type
0 to 11
2
M
CH
a2lt
A2LT: Alarm 2 Latch
OFF/ON
off
M
CH
ALH2:
alh2
Alarm 2 Hysteresis
0.02
0.01 to 99.99
M
CH
alt3
ALT3: Alarm 3 Type
0 to 11
2
M
CH
a3lt
A3LT: Alarm 3 Latch
OFF/ON
off
M
CH
ALH3:
alh3
Alarm 3 Hysteresis
0.02
0.01 to 99.99
M
<
CH
alt4
ALT4: Alarm 4 Type
0 to 11
2
M
CH
a4lt
A4LT: Alarm 4 Latch
OFF/ON
off
M
CH
ALH4:
alh4
Alarm 4 Hysteresis
0.02
0.01 to 99.99
M
<
8-74
l.3
Adjustment
Adjustment 2
Level
Level
l.adj
l.ad2
L key less
L key less
than 1 s
than 1 s
than 1 s
L key less than 1 s
Control stops.
Alarm Setting Level
Control Initial
Alarm Setting
Setting
Level
l.2
2 Level
L key
L key
less than 1 s
less than 1 s
L key less than 1 s
l.3
CH
REST:
rest
Standby Sequence Reset
a
Condition A or Condition B
M
sb1n
SB1N: Auxiliary Output 1
Open in Alarm
Nn-o
Close in alarm: N-O or
M
Open in alarm: N-C
sb2n
SB2N: Auxiliary Output 2
Open in Alarm
Nn-o
Close in alarm: N-O or
M
Open in alarm: N-C
sb3n
SB3N: Auxiliary Output 3
Open in Alarm
Nn-o
Close in alarm: N-O or
M
Open in alarm: N-C
sb4n
SB4N: Auxiliary Output 4
Open in Alarm
Nn-o
Close in alarm: N-O or
M
Open in alarm: N-C
SB5N: Auxiliary Output 5
sb5n
Open in Alarm
Nn-o
Close in alarm: N-O or
M
Open in alarm: N-C
SB6N: Auxiliary Output 6
sb6n
Open in Alarm
Nn-o
Close in alarm: N-O or
M
Open in alarm: N-C
SB7N: Auxiliary Output 7
sb7n
Open in Alarm
Nn-o
Close in alarm: N-O or
M
Open in alarm: N-C
<
SB8N: Auxiliary Output 8
sb8n
Open in Alarm
Nn-o
Close in alarm: N-O or
M
Open in alarm: N-C
SB9N: Auxiliary Output 9
sb9n
Open in Alarm
Nn-o
Close in alarm: N-O or
M
Open in alarm: N-C
SB10N: Auxiliary Output 10
sb10n
Open in Alarm
Nn-o
Close in alarm: N-O or
Open in alarm: N-C
M
<
)
Alarm Set
PID Setting
Setting
Level
l.alm
l.pid
Level
L key less
L key less
than 1 s
than 1 s
Display
Adjustment
l.3
Level
l.4
L key
L key
less than 1 s
less than 1 s
Approximation
Time Signal
Setting
Setting
Level
Level
l.tec
L key less
than 1 s
Communications
Setting
l.5
Level
Control in progress
Control stopped