Stopover Function And Resetting M Codes - Omron CS1W-MC221 - 02-2008 Operation Manual

Motion control units
Table of Contents

Advertisement

M Code Outputs
Example 1
Example 2
7-4-8

Stopover Function and Resetting M Codes

M000 to M499
Constant Acceleration Mode OFF
The following program will output an M code during pass operation. The M
code is reset from the CPU Unit.
N000 P000 X
N001 G01 X100 F100 M500
N002 G01 X200 F200 M501
B003 G01 X300 F100
N004 G79
X-axis operation
MC Unit
M strobe
M code
CPU Unit
M Code Reset
Constant Acceleration Mode ON
The following program will output an M code during pass operation. The M
code is reset from the CPU Unit.
N000 P000 X
N001 G01 X100 F100 M500
N002 G01 X200 F200 M501
B003 G01 X300 F100
N004 G79
X-axis operation
M strobe
MC Unit
M code
CPU Unit
M Code Reset
This section describes the reset timing for M codes when the Stopover func-
tion is used. Refer to 7-4-3 M Code Examples for details on the Stopover func-
tion.
When an M code between M000 and M499 is output, the next positioning
operation will be performed after positioning to the demand position has been
completed in either Pass Mode or In-position Check OFF Mode.
Section 7-4
437