Control Bit/Flag Timing Charts
20. Cycle Start Bit, Forced Block End Bit, M Code Reset Bit, and M Code Output
The Forced Block End Bit takes precedence and stops program execution when the Forced Block End Bit and
the M Code Reset BIt are turned ON at the same time. The M code is cleared when the program is stopped.
The program was already stopped, so program execution is not restarted when the M Code Reset Bit is turned
OFF.
21. Cycle Start Bit, Forced Block End Bit, M Code Reset Bit, and M Code Output
The program is stopped and the M code is cleared when the Forced Block End Bit goes ON.
22. Automatic/Manual Mode Bit and M Code Output
Automatic/Manual Mode Bit
M Code
Operation
The M code is not cleared when the Unit is switched to Manual Mode.
Cycle Start Bit
Forced Block End Bit
M Code Reset Bit
M Code
Operation
Cycle Start Bit
Forced Block End Bit
M Code Reset Bit
M Code
Operation
10
Appendix E
619