Interface Specifics
Timing Chart
Normal Operation:
Cycle Start Bit
(n+3, 02)
Program Number
(n+2)
Program Number Read Bit
(n+3, 07)
Program execution
Pass Operation:
Cycle Start Bit
Program execution
Speed
Axis operation
OFF: Stop
ON: Continue
P001 execution
The Cycle Start Bit is OFF, so execution is
stopped after N005 has been completed.
P002 execution
N003
G01
N004
G01
N005
G01
Time
Section 5-4
X100
F100
X300
F200
X400
F100
269