Origin Search Patterns
Reverse-mode Origin Search 7
This origin search is performed with an origin proximity signal input, and both phase-Z detection direction and
initial origin search direction set to CW.
Limit signal input
Origin proximity
signal input
Phase-Z signal
Speed
Note Operation will vary depending on the setting of the limit signal input.
Error
(No origin proximity signal.)
(See note.)
Error
(No origin proximity signal.)
(See note.)
Appendix F
Error
(No origin
proximity signal.)
(See note.)
Error
(No origin
proximity signal.)
(See note.)
(See note.)