Outline
1-1-8

List of Function Blocks

Category
Type
System
System
Common
Common
Block
Block
Control
Controller
Block
External
External
Controller
Controller
Block
Block
Operation
Alarm/Signal
Block
restrictions/
Hold
Arithmetic
20
The following function blocks are combined and used in Loop Control Units.
Block
Block name
model
000 System
Common
001 2-position
ON/OFF
002 3-position
ON/OFF
011 Basic PID
012 Advanced PID
013 Blended PID
014 Batch Flowrate
Capture
016 Fuzzy Logic
031 Indication and
Setting
032 Indication and
Operation
033 Ratio Setting
034 Indicator
045 ES100X
Controller
Terminal
110 4-Point Warning
Indicator
111 High/Low Alarm Provides the alarm contact outputs for the high and
112 Deviation Alarm Provides the alarm contact outputs for the deviation of
113 Rate-of-change
Operation and
Alarm
115 High/Low Limit
116 Deviation Limit
118 Analog Signal
Hold
121 Addition or
Subtraction
122 Multiplication
123 Division
126 Arithmetic
Operation
127 Range
Conversion
Function
Makes settings common to all function blocks and
outputs signals for the system.
2-position type ON/OFF controller
3-position type ON/OFF controller for heating/cooling
ON/OFF control
Performs basic PID control.
Performs PID with two degrees of freedom control for
enabling deviation/MV compensation, MV tracking,
etc.
Performs PIF control on the cumulative value
(cumulative deviation) between the accumulated value
PV and accumulated value Remote Set Point.
Functions to open the valve at a fixed opening until a
fixed batch accumulated value is reached.
Inputs up to eight analog inputs and then outputs up
to two analog outputs based on fuzzy inferences.
Manual setter with PV indication and and SP setting
functions
Manual setter with PV indication and MV setting
functions
Ratio and bias setter with PV indication and ratio
setting function
PV indicator with PV alarm
Performs monitoring and setting for an ES100X
Controller connected directly to the RS-232C port on
the Loop Control Unit.
Provides the alarm contact outputs for the high/high,
high, low, and low/low limits of single analog signals.
This function block provides the same function as the
Indicator block (model 034).
low limits of single analog signals.
two analog signals.
Provides the alarm contact outputs for the high and
low limits of rate-of-change operation when the analog
signal rate-of-change is output.
Limits the high and low limits of single analog signals.
Calculates the deviation between two analog signals,
and limits the deviation within that range.
Holds the maximum, minimum or instantaneous value
of single analog signals.
Performs addition/subtraction with gain and bias on up
to 4 analog signals.
Performs multiplication with gain and bias on up to 2
analog signals.
Performs division with gain and bias on up to 2 analog
signals.
Performs various math operation (trigonometric.
logorithmic, etc.) on floating-point decimal values
converted (to industrial units) from up to 8 analog
inputs.
Converts analog ranges for up to eight analog signals
based only on values input for 0% and 100% inputs
and 0% and 100% outputs.
Section
1-1
Allocatable
block
address
000
001 to 032
065 to 096
100 to 349
(Note: 349
is an
internal
switch in
CX-
Process
Tool (One
Block
Model 209
is already
allocated
as the
default.))