Related System Parameters - Omron CS1W-MC221 - 02-2008 Operation Manual

Motion control units
Table of Contents

Advertisement

Servo Lock and Unlock

6-14-2 Related System Parameters

Unit Parameters
Address
MC221
MC421
0FA6 (4006) 0FA6 (4006) R
Machine Parameters
Address
MC221
MC421
X axis
Y axis
Z axis
107B
1094
10AD
(4219)
(4244)
(4269)
107C
1095
10AE
(4220)
(4245)
(4270)
107D
1096
10AF
(4221)
(4246)
(4271)
The system parameters required for the output port settings and the wiring
check are all set using CX-Motion. The IORD instruction can be used for read-
ing only. Refer to the addresses shown in the following tables.
R/W
Name
Output port
setting
Specifies whether the output ports will be used for
general output or brake signal output. Bits 00 to 03
correspond to output ports 1 to 4 if the ports are
used for general output, and to axes X through U if
the ports are used for brake signal output.
X = 0: General output, X = 1: Brake signal output
R/W
Name
U axis
10C6
R
Wiring check
(4294)
10C7
R
Wiring check
(4295)
time
10C8
R
Wiring check
(4296)
pulses
Configuration
15
L+1
0015
0
0
0
0
0
Output port setting
Bit 03
00
L
Output port 1 (X axis)
Output port 2 (Y axis)
Output port 3 (Z axis)
Output port 4 (U axis)
Configuration
15
L+1
0015
0
0
0
0
Specifies whether the wiring check function is
used.
X = 0: The wiring check function is not used.
X = 1: The wiring check function is used.
15
L+1
03
0015
0
0
0
0
Wiring check time
Specifies the wiring check time within a range
of 0 to 99 (x 10 ms).
Range: 00 to 63 Hex (0 to 99 [x 10 ms])
15
L+1
03
0015
0
0
0
0
Number of wiring check pulses
Specifies the number of pulses to check the wir-
ing within a range of 0 to 999 pulses.
Range: 000 to 3E7 Hex (0 to 999 [pulses])
Section 6-14
L
03 00
0
0
L
03
00
0
0
0
X
L
07
00
0
0
11
L
00
0
Default
setting
Default
setting
355

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs1w-mc221Cs1w-mc221-v1Cs1w-mc421Cs1w-mc421-v1

Table of Contents