PLC Interface Area Lists
CS1W-MC421 PLC Interface Area Outputs (CPU Unit to MC Unit)
Word
Contents
n+6
Control Bits
00 to 15
for Task 3
n+7
00 to 15
n+8
Control Bits
00 to 15
for Task 4
n+9
00 to 15
580
Bit
Task 3 program number 0000 to 03E7 (4-digit hexadecimal) (Decimal: 0000
to 0999)
Refer to Control Bits for Task 1 in n+2.
Control Bits for Task 3
Refer to Control Bits for Task 1 in n+3.
Task 4 program number 0000 to 03E7 (4-digit hexadecimal) (Decimal: 0000
to 0999)
Refer to Control Bits for Task 1 in n+2.
Control Bits for Task 4
Refer to Control Bits for Task 1 in n+3.
n = CIO 2000 + 10 x unit number (words)