System Configuration and Wiring
System Parameter Settings
1,2,3...
1. Double-click the system parameters in the project workspace. The Unit
and memory parameters will be displayed.
Set the system parameters that are required for controlling the MC Unit. Some
of the defaults set by CX-Motion will be changed. Once the system parame-
ters have been set, transfer them to the MC Unit and save them in the flash
memory. For the task axis declaration, use the X and Y axes for task 1.
The following parameters require setting. Use default settings for other
parameters.
Type of
parameters
Machine
Minimum unit
parameters
Display unit
Pulse rate
Positive/negative software limit
Feed rate
Maximum feed rate
parameters
Maximum interpolation feed rate
High-speed origin search feed rate
Low-speed origin search feed rate
Maximum jog feed rate
When no axes are specified, set the same values for the X and Y axes.
Name
0.01
mm
1/100
X-axis – direction: –50.00
X-axis + direction: 600.00
Y-axis – direction: –50.00
Y-axis + direction: 600.00
4000.00
4000.00
400.00
40.00
400.00
Section 11-2
Set value
507