Checking For Wiring Errors; Changing The Mechanical Direction Of Operation - Omron CS1W-MC221 - 02-2008 Operation Manual

Motion control units
Table of Contents

Advertisement

Changing the Mechanical Direction of Operation

2-5-4

Checking for Wiring Errors

Wiring or Parameter Check
1,2,3...
Zero Balance Adjustment
1,2,3...
!Caution The Teaching Box can be used for monitoring the present position or output-
2-6
Changing the Mechanical Direction of Operation
With an MC Unit and a U-series Servo Driver, the following procedures can be
used to check whether or not there are any wiring errors.
1. Remove the servomotor from the machinery, and set the MC Unit machine
parameters so that the wiring check will not be performed.
2. Turn ON the power supply. If there is no servomotor runaway, the wiring
and machine parameters will be correct. If there is runaway, check the wir-
ing. If it is correct, change either the "rotation direction" or "encoder polar-
ity" machine parameter.
When the above procedure eliminates servomotor runaway, perform a zero
balance adjustment.
1. Connect the servomotor to the machinery.
2. Set the MC Unit machine parameters so that the wiring check will be per-
formed.
3. Turn ON the power supply (to the MC Unit and Servo Driver together). Do
not use servo-lock.
4. Execute an automatic offset adjustment at the Servo Driver, with servo-un-
lock still in effect at the MC Unit. For details on executing an automatic off-
set adjustment, refer to the Servo Driver manual.
5. Adjust the gain at the Servo Driver. It is convenient to use autotuning. For
details on Servo Driver autotuning, refer to the Servo Driver manual.
6. Adjust the gain at the MC Unit. If this is done by means of Servo Driver au-
totuning, read the Servo Driver's position loop gain and use CX-Motion to
set that value in the MC Unit's servo parameter.
7. Execute servo-lock at the MC Unit, and check for any wiring errors.
ting an analog voltage. In either case, be sure to take safety precautions such
as removing the motor from the machinery. For detail on performing these
operations, refer to the Teaching Box Operation Manual (W320).
Either of the following operations can be performed to change the mechanical
direction of operation after wiring has been completed:
• Change the wiring.
• Change the Servo Motor and MC Unit parameters.
The second method (changing the parameters) will be explained here.
As shown below, there are two parameters to be changed for the MC Unit,
and one to be changed for OMRON U-series and M-series Servo Drivers.
MC Unit parameters:
Servo Driver parameter: CCW direction
Rotation direction, encoder polarity
Section 2-6
141

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs1w-mc221Cs1w-mc221-v1Cs1w-mc421Cs1w-mc421-v1

Table of Contents