Omron CS1W-MC221 - 02-2008 Operation Manual page 691

Motion control units
Table of Contents

Advertisement

System Parameter Settings
Programmer:
Feedrate Parameters
Parameter
Max. high-speed feed rate
Max. interpolation feed rate
Origin search high speed
Origin search low speed
Max. jog feed rate
Accel./Decel. curve
Acceleration time
Deceleration time
Interpolation accel. time
Interpolation decel. time
MPG ratio/electronic gear
ratio 1 numerator
MPG ratio/electronic gear
ratio 1 denominator
MPG ratio/electronic gear
ratio 2 numerator
MPG ratio/electronic gear
ratio 2 denominator
MPG ratio/electronic gear
ratio 3 numerator
MPG ratio/electronic gear
ratio 3 denominator
MPG ratio/electronic gear
ratio 4 numerator
MPG ratio/electronic gear
ratio 4 denominator
Zone Parameters
Parameter
Zone 1 specification
Zone 1 valid timing
Zone 1
Negative
direction SV
Positive
direction SV
Zone 2 specification
Zone 2 valid timing
Zone 2
Negative
direction SV
Positive
direction SV
Zone 3 specification
664
Program Number:
Setting
X axis
Y axis
Setting
Date:
Z axis
U axis
Setting range
Enable or disable zone 1 settings
Valid after origin search or valid
even if origin search has not been
completed
–39,999,999 to 39,999,999
Enable or disable zone 2 settings
Valid after origin search or valid
even if origin search has not been
completed
–39,999,999 to 39,999,999
Enable or disable zone 3 settings
Appendix I
Page:
Setting range
1 to 39,999,999
Trapezoidal or
S-shaped
0 to 9,999 ms
–10,000 to 10,000
1 to 10,000
–10,000 to 10,000
1 to 10,000
–10,000 to 10,000
1 to 10,000
–10,000 to 10,000
1 to 10,000

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs1w-mc221Cs1w-mc221-v1Cs1w-mc421Cs1w-mc421-v1

Table of Contents