Honda Prelude 1993 Service Manual page 453

Hide thumbs Also See for Prelude 1993:
Table of Contents

Advertisement

-12, Turn the mainshaft holder bolt clockwise; stop
t u r n i n g w h e n t h e d i a l g a u g e h a s r e a c h e d i t s
maximum movement. The reading on the dial
gauge is the amount of mainshaft end play.
CAUTION: Turning iho mainshaft holder bolt
mor€ than 60 dogrecs after tho noodle of ths
d i a l g l u g a 3 t o p s m o v i n g m a y d a m a g o t h e
transmission.
MAINSHAFT HOLDER
07GAJ - FG20110
-13. lf the reading is within the standard. the clear-
ance is correct.
lf the reading is not within the standard. re-
check the shim thickness.
Strndard: 0.10 -
0.16 mm (0.00i1- 0.006 in)
Transmission
Reassembly
Install the differential assembly in the clutch hous-
i n g .
CLUTCH HOUSING
Install the spring washer and washer with the angle
against the clutch housing as shown
lnsert the mainshaft and countershaft into the shift
forks 8nd installthem as an assemblv.
NOTE: Before installing the mainshaft and counter-
shaft assemblies, tape the mainshaft splines to pro-
tect them.
MAINSHAFT
ASSEMBLY
Tape the mainshaft
splrn6.
(cont'd )
OIFFERENTIAL ASSEMBLY
DIAL GAUGE
13-37

Advertisement

Table of Contents
loading

Table of Contents