Alarm Vdsl2 Channel Profile Setup - ZyXEL Communications MSC1024G Series User Manual

Managment switch card
Hide thumbs Also See for MSC1024G Series:
Table of Contents

Advertisement

The following table describes the labels in this screen.
Table 157 Profile > Alarm VDSL2 > LineProfile
LABEL
Name
15 Min
FailedFullInt
Threshold
XTUC
XTUR
15 Minute FECS
Threshold
15 Minute ES
Threshold
15 Minute SES
Threshold
15 Minute LOSS
Threshold
15 Minute UAS
Threshold
15 Minute LOFS
Threshold
15 Minute LPRS
Threshold
Apply
New
Cancel
Index
Name
Modify
Delete

13.16.2 Alarm VDSL2 Channel Profile Setup

Click the ChanProfile link at the top-right corner of the Alarm VDSL2 screen to display the
screen as shown. Use this screen to view, add, edit, modify a VDSL channel alarm profile.
The device sends an alarm trap and generates a syslog entry when the thresholds of the alarm
profile are exceeded.
MSC1000G/1024G/1224G Series User's Guide
DESCRIPTION
Enter a descriptive name for identification purposes.
Enter the number of times a full initialization is allowed to fail within 15 minutes.
Configure the thresholds in this column for the system (XTUC).
Configure the thresholds in this column for CPE devices (XTUR).
Enter the number of Forward Error Correction Seconds (FECS) that are permitted
to occur within 15 minutes.
Enter the number of Errored Seconds (ES) that are permitted to occur within 15
minutes.
Enter the number of Severely Errored Seconds (SES) that are permitted to occur
within 15 minutes.
Enter the number of Loss Of Signals Seconds (LOSS) that are permitted to occur
within 15 minutes.
Enter the number of UnAvailable Seconds (UAS) that are permitted to occur within
15 minutes.
Enter the number of Loss Of Framing Seconds (LOFS) that are permitted to occur
within 15 minutes.
Enter the number of times a Loss of PoweR Seconds (LPRS) is permitted to occur
within 15 minutes.
Click Apply to save the changes in this screen to the system's volatile memory.
The system loses these changes if it is turned off or loses power, so use the
Config Save on the navigation panel and then the Save button to save your
changes to the non-volatile memory when you are done configuring.
While you are modifying a profile, you can click New to start configuring a fresh
profile without saving your changes.
Click Cancel to start configuring the screen again.
This is the index number of the alarm profile.
This field displays the descriptive name for the alarm profile.
Select a profile's Select radio button and click Modify to edit the profile.
Select a profile's Select radio button and click Delete to remove the profile.
Chapter 13 Profile Screens
359