Chapter 15 Switch Screens
The following table describes the labels in this screen.
Table 258 CFM Endpoint: MEP
LABEL
MD Name
MA Name
Endpoint ID
Port
Direction
Priority
CCI-enabled
Alarm Time
Reset Time
MAC Address
Apply
New
Cancel
Index
MEP ID
Port
Direction
Priority
CCI-enabled
Modify
Delete

15.17.3 CFM Endpoint Screen: MIP

Click an MA index number in the Switch > CFM > CFM maintenance association screen
and then the MIP tab to display the screen shown next. Use this screen to configure
Maintenance association Intermediate Points (MIPs) under an MA.
500
DESCRIPTION
This displays the name of the MD for which you want to configure end points.
This displays the name of the MA for which you want to configure end points.
Select a valid MEP ID which is defined in the CFM maintenance association
screen.
This binds the MEP ID to a physical port on the device. You can select an Ethernet
port (enet1 or enet2) or select a DSL port (by specifying a slot number and port
number of a line card).
Select whether to send CCMs (Connectivity Check Messages) from the end point
you selected in this screen (when you select down) or from (s) (when you select
up). Select up only when the link of the specified end point is down.
Select the priority level for the CCMs configured in this screen. "0" is the lowest
priority level and "7" is the highest.
Select this to enable CCMs sending from the end point configured in this screen.
Deselect this to stop CCMs sending.
This is the number of seconds the MSC waits to send a local alarm after three
CFM_ERROR events have been detected.
This is the number of seconds the MSC waits to cancel a local alarm after a
CFM_ERROR event has been resolved and no other alarms that have occurred.
Enter the CFM end point's MAC address.
Click Apply to add the settings as a new entry in the summary table above.
Click New to start configuring an MA setting.
Click Cancel to reset the fields.
This field displays the index number of an end point.
This field displays the MEP ID of the end point used when you need to do a CFM
test or view the CFM statistics.
This field displays the end point's physical port on the device.
This field displays whether to send CCMs (Connectivity Check Messages) from
the end point you configured (down) or from (s) (up).
This field displays the priority of the end point.
This field displays the CCMs is sending for the configured end point or not.
Select an end point and click Modify to bring the end point's information shown in
this screen for modification.
Select an end point and click Delete to remove it.
MSC1000G/1024G/1224G Series User's Guide