Dtpvc Show Command; Port Enable Command; Port E1 Commands - ZyXEL Communications MSC1024G Series User Manual

Managment switch card
Hide thumbs Also See for MSC1024G Series:
Table of Contents

Advertisement

Chapter 31 port Commands

31.7.5 dtpvc show command

Syntax:
port dtpvc show <slot>|<slot-port>
This command displays the DTPVC configuration for the specified subscriber slot or port. The
following example displays the DTPVC configuration for the line card in slot 5.
ras> port dtpvc show 5
pvc
--------------- ---- ----- ---- ---- ---- ---- - ---------------------------
5-1-8/35

31.8 port enable Command

Syntax:
port enable <slot-port>
This command turns on the specified subscriber port(s).
The following example turns on port 5 on the line card in slot 7.
ras> port enable 7-5

31.9 port e1 Commands

Syntax:
port e1 alarmprof <slot-port> <profile>
This command sets the alarm profile used for the specified E1 port.
Syntax:
port e1 impedance <slot-port> 75|120
This command sets the impedance to 75 ohm (coaxial cabling) or 120 ohm (twisted-pair
cabling) for the specified E1 port.
Syntax:
port e1 timingsrc <slot-port> local|<port>
This command sets the time source for the selected E1 port. Use this command to have the
selected E1 port Either use the clock of the IMA line card (local) or use the clock of the
connected ADM device through an E1 line (1~8).
The following example sets the alarm profile, impedance and time source for E1 port 1 on slot
2 to ATM-profile1, 120 ohm and local time source.
ras> port e1 alarmprof 2-1 ATM-profile1
ras> port e1 impedance 2-1 120
ras> port e1 timingsrc 2-1 local