ZyXEL Communications MSC1024G Series User Manual page 667

Managment switch card
Hide thumbs Also See for MSC1024G Series:
Table of Contents

Advertisement

The following table describes labels in the example.
Table 321 lcman show Command
LABEL
id
state
card type
uptime
f/w version
heat
vol
mon
down
out
The following example shows information about the line card installed in slot 1.
ras> lcman show 1
slot1 SLC1248G-22:
uptime: 01:33:24
status:
hardware sensor: ok
temperature
voltage
module exist
module status
inventory information:
hardware version: AA
hardware serial number: Z51854282
firmware version: V3.70(ABF.0)b5 | 11/07/2006
DSL driver version: 0.9.1.0
DSL modem version: 1.1-1.5.0__004
current voltage level:
1.8V:
3.3V:
15.0V: 14.961
'*' indicates a current alarm
MSC1000G/1024G/1224G Series User's Guide
DESCRIPTION
This is the slot number.
This displays whether or not the installed card is turned on.
This identifies the model of card that is installed or was last installed in the
slot.
This is how long the card has been active.
This is the release of firmware that the card is using.
The following columns display a "V" if an alarm has been detected. "-"
displays if no related alarm has been detected.
This displays whether or not there is an alarm due to the card's temperature
being too high or too low.
This displays whether or not there is an alarm due to the card's voltage being
too high or too low.
This displays whether or not the hardware monitor sensor has failed.
This displays whether or not the installed card is down (inactive).
This displays whether the card is installed or has been removed.
: ok
: ok
: ok
: ok
current temperature:
1.777
Temp1: 37.000
3.320
Temp2: 41.000
Temp3: 38.000