Link 15Min - ZyXEL Communications MSC1024G Series User Manual

Managment switch card
Hide thumbs Also See for MSC1024G Series:
Table of Contents

Advertisement

Chapter 14 Statistics Screens
Table 225 IMA Statistics: IMA Line Card: Group Detail: Link Detail (continued)
LABEL
Test Processing
Status
Valid 15 minutes
Interval
Invalid 15 minutes
Interval
TimeElapsed(secs
)
Ne State
Fe State
NeFailureStatus
FeFailurStatus
link ID
NeUnusableSecs(
secs)
FeUnusableSecs(
secs)
Ne Num Failures
Fe Num Failures
Stuffs
TestPattern

14.23.4 Link 15Min

To display the performance of an E1 link on the selected IMA group for the current 15
minutes, click the slot number in the Statistics > IMA screen, the index number of the IMA
group (see
458
DESCRIPTION
The field displays the current state of the Test Pattern Procedure.
disabled: The test is stopped.
operating: The test is running and no error has been detected on the link.
linkFail: An error has been detected on this link during the test.
The field displays the number of 15 minute intervals for which valid data was
collected. The value should be 96 unless the IMA group table entry was created
within the last 24 hours. In which case the value will be the number of complete
15 minute intervals since the IMA group table entry was created.
The field displays the number of 15 minute intervals for which no valid data was
available.
The field displays the number of seconds that have elapsed since the beginning
of the current measurement period.
The field displays the current state of the transmission (Tx) or receiving (Rx) link
reported by the IMA line card.
The field displays the current state of the transmission (Tx) or receiving (Rx) link
reported via ICP cells by the remote IMA device.
The field displays the current link failure status of the receiving link reported by
the IMA line card.
The field displays the current link failure status of the receiving link reported via
ICP cells by the remote IMA device.
The field displays the outgoing link identifier (LID) used currently on the link by the
IMA line card (Tx) or by the remote IMA device (Rx).
The field displays the number of unusable seconds in transmission (Tx) or
receiving (Rx) direction detected by the IMA line card.
The field displays the number of unusable seconds in transmission (Tx) or
receiving (Rx) direction detected by the remote IMA device.
The field displays the number of times a transmission (Tx) or receiving (Rx)
failure alarm that have occurred on this link detected by the IMA line card.
The field displays the number of times a transmission (Tx) or receiving (Rx)
failure alarm that have occurred on this link detected by the remote IMA device.
The field displays the number of stuff events inserted in the transmission (Tx) or
receiving (Rx) direction.
The field displays the test pattern received in an ICP cell on the link during the
IMA Test Pattern Procedure. This value may then be compared to the transmitted
test pattern.
Figure 311 on page
452) and then the number of a link and the Link 15Min tab.