ZyXEL Communications MSC1024G Series User Manual page 281

Managment switch card
Hide thumbs Also See for MSC1024G Series:
Table of Contents

Advertisement

Table 116 Port > VoIP SIP Setup Screen
LABEL
DSP Profile
Customer Information
TEL
Impedance
Op Mode
Tx / Rx Gain
Apply
Cancel
Copy
MSC1000G/1024G/1224G Series User's Guide
Chapter 11 Subscriber Port Setup Screens
DESCRIPTION
Select the digital signal processing profile the port is to use. A DSP profile
contains information about the codecs (coders/decoders)
If you have not configured any profiles, only the default profile DEFVAL
can be selected. Configure DSP profiles in the Profile > VoIP DSP
screen.
Enter information to identify the subscriber connected to this port. You can
use up to 31 printable ASCII characters (including spaces and hyphens).
Enter the telephone number of the subscriber VoIP port. This is used as
part of the port's SIP URI.
This field displays the default VoIP port AC impedance. The default
impedance value depends on the country code (configured in the VoIP >
Countrycode screen).
If you do not want to use the default impedance, select the required AC
impedance of the VoIP port from the drop-down list.
Set the port's VoIP operation mode.
Select DEFVAL to use SIP to connect to a server.
Select v5sip to use V5.2 to connect to a traditional class 5 POTS switch.
Tx: Enter the amount of gain (increase in volume) you want to apply to the
signal received from the subscriber and transmitted to the SIP server.
Rx: Enter the amount of gain (increase in volume) you want to apply to
the signal received from the SIP server and transmitted to the subscriber.
These are measured in tenths of a decibel and the range can be from -
200 to 200.
Enter a negative value to decrease the volume.
Click this to save your changes to the MSC's volatile memory. The MSC
loses these changes if it is turned off or loses power, so use the Config
Save link on the navigation panel to save your changes to the non-volatile
memory when you are done configuring.
Click this to begin configuring the fields again.
Use this to assign a port's settings to other ports.
1. Click Copy. The following pop-up screen displays.
Figure 174 Copy Port Settings
2. Select the required slot from the drop-down list.
3. Select the port(s) to which you want to copy the settings. Use Select
All to select every port. Use Select None to clear all of the check
boxes.
4. Click Apply to copy the settings, or click Cancel to close the window
without saving any changes.