ZyXEL Communications MSC1024G Series User Manual page 181

Managment switch card
Hide thumbs Also See for MSC1024G Series:
Table of Contents

Advertisement

Figure 96 Diagnostic > MLT Screen
The following table describes the labels in this screen.
Table 60 Diagnostic > MLT Screen
LABEL
MLT
Forced
Test
Set
Get MLT Data
Get Relay Data
The following MLT options are available only in Test mode.
MSC1000G/1024G/1224G Series User's Guide
DESCRIPTION
Use the Slot and Port drop-down list boxes to select the port on an active
VoIP line card you want to configure.
Select Test to perform line tests directly from the MSC.
Select Relay to allow or prohibit line testing performed by external
devices connected to the VOP line cards Test In and Test Out ports.
When you select Relay, also select the MLT relay mode:
In: allow diagnostic inner loop tests to be initiated by an external device.
Out: allow diagnostic outer loop tests to be initiated by an external device.
Off: forbid MLT relay testing.
Both: allow both inner and outer loop diagnostic tests to be initiated by an
external device.
In Relay mode, select this to make the configuration change immediately,
even if the port is currently in use.
In Test mode, click this to perform the specified test.
In Relay mode, click this to save the current settings (you must also click
the Config Save link on the navigation panel to save your changes to the
non-volatile memory when you are done configuring).
Click this to see the results of the latest MLT test performed on the
specified line card and port.
Click this to see the current MLT relay configuration of the specified line
card.
Chapter 8 Diagnostic Screens
181