C
H A P T E R
This chapter shows you how to use the
32.1 Profiles Overview
Profiles are groups of settings that you can assign to a port(s). This helps simplify and speed
up port configuration.
32.2 General profile Command Parameters
The following table describes commonly used
Table 326 General profile Command Parameters
NOTATION
profile
MSC1000G/1024G/1224G Series User's Guide
profile Commands
profile
DESCRIPTION
The profile name, up to 31 characters.
Alarm profile settings
: near end
atuc
atur
: far end
lofs:
The maximum time there is loss of framing (0~900 seconds).
The maximum time there is a loss of signal (0~900 seconds).
loss:
lols:
The maximum time there is a loss of link (0~900 seconds).
lprs:
The maximum time there is a loss of power (0~900 seconds).
ess:
The maximum time there is error (0~900 seconds).
ffr:
The maximum time there are failed fast retrains (0~900 seconds).
The maximum time there are severe errors on the line (0~900 seconds).
sesl:
uasl:
The maximum time there the line is unavailable (0~900 seconds).
fru:
The maximum transmission rate (0~2147483 Kbps).
The maximum interleave rate (0~2147483 Kbps).
iru:
frd:
The minimum transmission rate (0~2147483 Kbps).
ird:
The minimum interleave rate (0~2147483 Kbps).
ift:
Enables (1) or disables (0) the init failure trap.