Chapter 32 profile Commands
The following example displays the default alarm VDSL profile (DEFVAL).
ras> profile alarmvdsl show DEFVAL
vdsl alarm profile : DEFVAL
initFailure(ift)
15MinLofs(lofs)
15MinLoss(loss)
15MinLols(lols)
15MinLprs(lprs)
15MinESs(ess)
15MinSesL(sesl)
15MinUasL(uasl)
ras>

32.9.2 profile alarmvdsl set Command

Syntax:
profile alarmvdsl set <profile> [lofs <lofs>] [loss <loss>] [lols <lols>]
[lprs <lprs>] [ess <ess>] [sesl <sesl>] [uasl <uasl>] [ift <ift>]
where
The
alarmprofile set
sends an alarm trap and generates a syslog entry when the thresholds of the alarm profile are
exceeded.
Configure
use them with specific VDSL ports.
782
(sec):
(sec):
(sec):
(sec):
(sec):
(sec):
(sec):
=
A name for the alarm profile (up to 31 English keyboard
<profile>
characters).
The number of Loss Of Frame Seconds (0~900) that are
=
<lofs>
permitted to occur within 15 minutes.
The number of Loss Of Signal Seconds (0~900) that are
=
<loss>
permitted to occur within 15 minutes.
The number of Loss Of Link Seconds (0~900) that are permitted
=
<lols>
to occur within 15 minutes.
The Number of Loss of PoweR seconds (0~900) permitted to
=
<lprs>
occur (on the ATUR) within 15 minutes.
The number of Errored SecondS (0~900) that are permitted to
=
<ess>
occur within 15 minutes.
The number of Severely Errored Seconds (0~900) that are
<sesl>
=
permitted to occur within 15 minutes.
The number of UnAvailable Seconds (0~900) that are permitted
<uasl>
=
to occur within 15 minutes.
A rate in kilobits per second (Kbps). If an interleave mode
<iru>
=
connection's upstream transmission rate increases by more than
this number, then a trap is sent.
=
"1" sets the profile to trigger an alarm for an initialization failure
<ift>
trap. "0" sets the profile to not trigger an alarm for an initialization
failure trap.
command configures VDSL port alarm thresholds. The system
profiles first and then use the
alarmvdsl
:
-
0
0
0
0
0
0
0
port vdsl alarmprof