Error Messages In Hp-Gl Command Mode - GRAPHTEC FC 4500 Series Service Manual

Cutting plotter
Hide thumbs Also See for FC 4500 Series:
Table of Contents

Advertisement

9.6

Error Messages in HP-GL Command Mode

If any of the HP-GL command error messages listed in the following table is displayed, the cause can
nearly always be traced to one of the causes below:
The software application's output device setting has changed; or
The plotter's interface conditions have changed.
If a command error occurs while the COMMAND setting is HP-GL, therefore, first check the two
corresponding points below.
Configure the software to drive your plotter and ensure that the software's interface conditions are
correctly set; and
Re-specify the plotter's interface conditions.
Error message
ERROR 1
Instruction not recognized
ERROR 2
Wrong number of parameters
ERROR 3
Out of range parameters
ERROR 5
Unknown character set
ERROR 6
Position overflow
ERROR 7
Buffer overflow
ERROR 10
Invalid I/O output request
ERROR 11
Invalid byte following ESC
ERROR 12
Invalid byte in I/O Control
ERROR 13
Out of range I/O parameter
ERROR 14
Too many I/O parameters
ERROR 15
Error in I/O transmission
ERROR 16
I/O buffer overflow
FC4500-UM-251-9370
Cause
An unrecognizable command was
issued.
A command was issued with the
wrong number of parameters.
A command containing an invalid
parameter was issued.
An unknown character set was
specified.
A command was issued with
coordinate data that exceeds the
effective cutting/plotting area.
The data being input exceed the
capacity of the downloadable
character buffer, polygon buffer,
etc.
While executing an output
command, the plotter received
another output command.
Receipt of the ESC character was
followed by an invalid byte.
A device control command
containing an invalid byte was
received.
An I/O control command was
issued with parameter outside of
the permissible numeric range.
An I/O control command was
issued with too many parameters.
During data transfer, a framing
error, parity error, or overrun error
occurred.
The I/O buffer received data faster
than it could process the data.
147
9 TROUBLE SHOOTING
Solution
Issue a command that the plotter
will recognize.
Re-issue the command with the
correct number of parameters.
Re-issue the command with its
parameters specified within their
permissible ranges.
Specify a character set that the
plotter will recognize.
Issue the command with its
coordinate data specified within
the effective cutting/plotting area.
Increase the buffer size.
Check the programmed data.
Check the programmed data.
Check the programmed data.
Check the programmed data.
Check the programmed data.
Check the settings of the RS-
232C interface conditions.
Check the settings of the RS-
232C interface conditions.

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FC 4500 Series and is the answer not in the manual?

This manual is also suitable for:

Fc4500-50Fc4550-50Fc4500-60Fc4510-60

Table of Contents