17.1.4 NX700 Series (Ethernet)
Communication Setting
Editor
Make the following settings on the editor. For more information, see "1.3.2 Ethernet Communication".
IP address for the V9 unit
- When specified on the screen program:
[System Setting] [Hardware Setting] [Local Port IP Address]
- When specified on the V9 unit:
Local mode [LAN Setting]
Port number for the V9 unit (for communication with PLC)
[System Setting] [Hardware Setting] [PLC Properties] [Communication Setting]
Others
[System Setting] [Hardware Setting] [PLC Properties] [Communication Setting]
Item
Header
Monitor Registration
Local Port No.
* For settings other than the above, see "1.4 Hardware Settings".
Select a format of communication with the PLC.
% (Header) / < (Extension Header)
Select [Yes] in the case where a monitor registration command is used for communication with the PLC.
* One V9 unit can be registered as a monitor for one PLC. Do not select [Yes] for multiple V9 units in n : 1
connection.
Set the local port number of the V9 unit (1 to 31).
Set the same number as the one set for "Target node MEWTOCOL station number" on the [Connection
Setting] dialog of the PLC.
17.1 PLC Connection
Contents
17-11