Fuji Electric Monitouch V9 Series Connection Manual page 258

Hide thumbs Also See for Monitouch V9 Series:
Table of Contents

Advertisement

9.2.3
MR-J2S-*A
Communication Setting
Editor
Communication setting
Item
Connection Mode
Signal Level
Baud Rate
Data Length
Stop Bit
Parity
Target Port No.
Servo amplifier
Extension setting parameters
To make the parameter setting valid, the power supply is turned on again.
Parameter
Symbol
No.
15
16
53
1 : 1 / 1 : n / Multi-link2 /
Multi-link2 (Ethernet) /
1 : n Multi-link2 (Ethernet)
RS-232C / RS-422/485
9600 / 19200 / 38400 / 57600 bps
8 bits (fixed)
Item
SNO
Station number setting
BPS
Communication function selection
OP8
Function selection 8
9.2 Temperature Controller/Servo/Inverter Connection
Setting
1 bit (fixed)
Even (fixed)
0 to 31
0 to 31
0
0
(Underlined setting: default)
Remarks
(Underlined setting: default)
Setting Example
0
Baud rate
0: 9600 bps
1: 19200 bps
2: 38400 bps
3: 57600 bps
Serial communication selection
0: RS-232C
1: RS-422
Response delay time
0: Invalid
1: Valid
0
Sum check for protocol
0: Provided
Station number selection for protocol
0: With station number
9-65