Fuji Electric Monitouch V9 Series Connection Manual page 261

Hide thumbs Also See for Monitouch V9 Series:
Table of Contents

Advertisement

9-68
9. MITSUBISHI ELECTRIC
06A
(basic setting parameters upper limit)
06B
(gain/filter parameters upper limit)
06C
(extension setting parameters upper limit)
06D
(I/O setting parameters upper limit)
F06A
(basic setting parameters upper limit)
F06B
(gain/filter parameters upper limit)
F06C
(extension setting parameters upper limit)
F06D
(I/O setting parameters upper limit)
07A
(basic setting parameters lower limit)
07B
(gain/filter parameters lower limit)
07C
(extension setting parameters lower limit)
07D
(I/O setting parameters lower limit)
F07A
(basic setting parameters lower limit)
F07B
(gain/filter parameters lower limit)
F07C
(extension setting parameters lower limit)
F07D
(I/O setting parameters lower limit)
S08A
(basic setting parameters symbol)
S08B
(gain/filter parameters symbol)
S08C
(extension setting parameters symbol)
S08D
(I/O setting parameters symbol)
09A
(write enable/disable of basic setting parameters)
09B
(write enable/disable of Gain/filter parameters)
09C
(write enable/disable of Extension setting parameters)
09D
(write enable/disable of I/O setting parameters)
Set the target device memory on the [Device Input] dialog.
 RAM:
Stored in RAM
 EEPROM:
Stored in RAM + EEPROM
Indirect Device Memory Designation
 Address No. 0 to 65535
n+0
n+1
n+2
n+3
* Expansion code
15
0
Expansion bits
0: 0 to 15 bits
1: 16 to 31 bits
PLC_CTL
Macro command "PLC_CTL F0 F1 F2"
Contents
Software version
Device Memory
15
8 7
Models
Address No.
Expansion code *
00
0
0
0
0
0
F0
n
n + 1
1 - 8
(PLC1 - 8)
n + 2
n+3 to n+10
TYPE
1EH
Double-word, read only
1FH
Double-word, read only
20H
Double-word, read only
21H
Double-word, read only
22H
Real number, read only
23H
Real number, read only
24H
Real number, read only
25H
Real number, read only
1EH
Double-word, read only
1FH
Double-word, read only
20H
Double-word, read only
21H
Double-word, read only
22H
Real number, read only
23H
Real number, read only
24H
Real number, read only
25H
Real number, read only
2EH
Read only
2FH
Read only
30H
Read only
31H
Read only
32H
Read only
33H
Read only
34H
Read only
35H
Read only
0
Device Type
Bit designation
Station number
8
0: RAM
1: RAM+EEPROM
F1 (= $u n)
Station number
Command: 0002H
Data No. 0070H
Software version
Remarks
Return data: Data stored from controller to V series
F2
3