PLC_CTL
Macro command "PLC_CTL F0 F1 F2"
Contents
Writing running
frequency (EEPROM)
Writing running
frequency (RAM)
All alarms clear
Operation command
All parameter clear
Inverter reset
F0
n
Station number
1 - 8
n + 1
Command: 00EEH
(PLC1 - 8)
n + 2
Running frequency
n
Station number
1 - 8
n + 1
Command: 00EDH
(PLC1 - 8)
n + 2
Running frequency
n
Station number
1 - 8
(PLC1 - 8)
n + 1
Command: 00F4H
n
Station number
n + 1
Command: 00FAH
1 - 8
0000H: Stop
(PLC1 - 8)
n + 2
0002H: Normal rotation (STF)
0004H: Reverse rotation (STR)
n
Station number
n + 1
Command: 00FCH
Data
1 - 8
(PLC1 - 8)
9696H
n + 2
9966H
5A5AH
55AAH
n
Station number
1 - 8
(PLC1 - 8)
n+1
Command: 00FDH
9.2 Temperature Controller/Servo/Inverter Connection
F1 (= $u n)
Pr.
Communication
Calibration
Pr.
9-61
00ECH
Other Pr.
00F3H
00FFH
F2
3
3
2
3
3
2