4. JTEKT
Available Device Memory
The available setting range of device memory varies depending on the PLC model. Be sure to set within the range available for
the PLC to be used. Use [TYPE] when assigning indirect device memory for macro programs.
D
(data register)
R
(link register)
B
(file register)
N
(current value register)
X
(input)
Y
(output)
M
(internal relay)
K
(keep relay)
L
(link relay)
T
(timer/contact)
C
(counter/contact)
U
(extensional data register)
H
(extensional set value register)
EN
(extensional current value register)
EX
(extensional input)
EY
(extensional output)
EM
(extensional internal relay)
EK
(extensional keep relay)
EL
(extensional link relay)
ET
(extensional timer/contact)
EC
(extensional counter/contact)
V
(special register)
PRG No. setting
If [Transmission Mode: Data Area Division] is set under [Communication Setting], specify a program number ([PRG No.]) in
addition to device type and address number. The assigned device memory is expressed as shown below when editing the
screen. The PRG No. is invalid for the device memory in the common area.
Indirect Device Memory Designation
 For the address number of 0 to 65535:
15
n+0
n+1
n+2
Expansion code
n+3
* If [Transmission Mode: Data Area Division] is set under [Communication Setting], specify a program number ([PRG No.])
for the expansion code.
Specify the number obtained by subtracting "1" from the actual program number ([PRG No.]) as defined below.
PRG No. 1: 0
PRG No. 2: 1
PRG No. 3: 2
Device Memory
8 7
Model
Device type
Address No.
*
Bit designation
00
Station number
TYPE
00H
PRG No. when [Data Area Division] is selected
01H
PRG No. when [Data Area Division] is selected
02H
PRG No. when [Data Area Division] is selected
03H
PRG No. when [Data Area Division] is selected
04H
WX as word device
05H
WY as word device
WM as word device, PRG No. when [Data Area Division] is
06H
selected
WK as word device, PRG No. when [Data Area Division] is
07H
selected
WL as word device, PRG No. when [Data Area Division] is
08H
selected
WT as word device, PRG No. when [Data Area Division] is
09H
selected
WC as word device, PRG No. when [Data Area Division] is
0AH
selected
0BH
0CH
0DH
0EH
WEX as word device
0FH
WEY as word device
10H
WEM as word device
11H
WEK as word device
12H
WEL as word device
13H
WET as word device
14H
WEC as word device
15H
WV as word device
 For the address number of 65536 or greater:
0
15
n+0
Model
n+1
n+2
n+3
Expansion code
n+4
Remarks
Example: 1: D0000
Address number
Device type
PRG No.: 1 to 3
8 7
Device type
Lower address No.
Higher address No.
*
Bit designation
00
Station number
0

Hide quick links: