15-16
15. Panasonic
15.1.5 FP7 Series (RS232C/422)
Communication Setting
Editor
Communication setting
Item
Connection Mode
Signal Level
Baud Rate
Data Length
Stop Bit
Parity
Target Port No.
PLC
FP7 configuration
Make PLC settings using the programming tool "FPWIN GR7".
For more information, refer to the PLC manual issued by the manufacturer.
Built-in SCU
COM 2 setting
*1
When using communication cassettes, configure CH1 and CH2 as COM1 and COM2 respectively.
CH1 = COM1
CH2 = COM2
AFP7CCS2
5Wire
3Wire
AFP7CCM1/AFP7CCM2
RS-422
RS-485
1 : 1 / 1 : n / Multi-link / Multi-link2 /
Multi-link2 (Ethernet) /
1 : n Multi-link2 (Ethernet)
RS-232C / RS-422/485
4800 / 9600 / 19200 / 38400 / 57600 /
None / Odd / Even
Setting Items
Communication mode
Target port No.
Baud rate
Data length
Parity
COM0 setting
Stop bit
*1
COM1 setting
CS/RS
*1
Transmission latency setting
Beginning code STX
Terminating resistance
Modem initialization
Setting Items
Signal line change
Setting Item
RS-422
Signal level change
RS-485
ON
Terminating
resistance setting
OFF
Setting
115K bps
7 / 8 bits
1 / 2 bits
0 to 255
MEWTOCOL-7
1 to 255
4800 / 9600 / 19200 / 38400 / 57600 / 115K bps
7 / 8 bits
None / Odd / Even
1 / 2 bits
Invalid
For RS-232C, RS-422 communication: 0
For RS-485 communication: Change depending on environment
Invalid
CR
No initialization
Contents
3W
Contents
RS-485
ON at termination
(Underlined setting: default)
Remarks
(Underlined setting: default)
Descriptions
Remarks
Set all switches to 3W.
Remarks
Turn on all three switches of the CH
for connection.