7.1.2

SR-T (K Protocol)

Communication Setting
Editor
Communication setting
Connection Mode
Signal Level
Baud Rate
Data Length
Stop Bit
Parity
Target Port No.
PLC
Universal Communication Port
No particular setting is necessary on the PLC. The PLC always performs communication functions using the following
parameters. Set the following parameters under [Communication Setting] of the editor.
Baud rate
Parity
Data length
Stop bit
Data type
Calendar
This model is not equipped with the calendar function. Use the built-in clock of the V series.
Available Device Memory
The available setting range of device memory varies depending on the PLC model. Be sure to set within the range available for
the PLC to be used. Use [TYPE] when assigning indirect device memory for macro programs.
D
(word device)
X
(input)
Y
(output)
M
(internal relay)
S
(stage)
K
(keep relay)
L
(link relay)
T
(timer/contact)
C
(counter/contact)
Item
Item
Device Memory
Setting
1 : 1 / Multi-link2 /
Multi-link2 (Ethernet)
RS-422/485
19200
8 bits
1 bit
Odd
0 to 31
Setting
19200 bps
Odd
8 bits
1 bit
HEX
TYPE
00H
01H
Common to X and Y
02H
Common to X and Y
03H
04H
05H
06H
07H
08H
7.1 PLC Connection
(Underlined setting: default)